The Lexseco
Core Loss Tester provides high current at low voltage to simulate
operating conditions in the core. Flux, amperes and watts readings,
and core dimensions, are fed into the Tester's computer system
which calculates watts/lb. (kg) of core loss. With parameters
for "bad", "marginal" and "good"
cores, the software generates a detailed printed core condition
report. Localized damage is found by increasing the excitation
level to reveal hot spots within the core.